Find the best KORE solution for you*
(select an Energy Rating)
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.12 |
200mm Silver |
| Full Fill Cavity Wall |
KORE Fill + KORE Linear Drylining |
0.12 |
200mm Silver + 40mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.12 |
160mm Silver + 65mm Silver |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.12 |
250mm Silver + 40mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.12 |
265mm Silver + 35mm Silver |
| Flat Ceiling |
KORE Pack |
0.12 |
300mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.12 |
200mm Silver |
| Full Fill Cavity Wall |
KORE Fill |
0.15 |
200mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.15 |
150mm Silver + 40mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.12 |
250mm Silver + 40mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.12 |
265mm Silver + 35mm Silver |
| Flat Ceiling |
KORE Pack |
0.12 |
300mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.16 |
150mm Silver |
| Full Fill Cavity Wall |
KORE Fill |
0.20 |
150mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.20 |
100mm Silver + 40mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.14 |
200mm Silver + 40mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.14 |
210mm Silver + 35mm Silver |
| Flat Ceiling |
KORE Pack |
0.14 |
260mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.18 |
125mm Silver |
| Full Fill Cavity Wall |
KORE Fill |
0.22 |
135mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.22 |
85mm Silver + 40mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.16 |
180mm Silver + 25mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.16 |
190mm Silver + 25mm Silver |
| Flat Ceiling |
KORE Pack |
0.14 |
260mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.22 |
115mm White |
| Full Fill Cavity Wall |
KORE Fill |
0.25 |
120mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.25 |
70mm Silver + 40mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
115mm Silver + 25mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
125mm Silver + 25mm Silver |
| Flat Ceiling |
KORE Pack |
0.16 |
225mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.25 |
100mm White |
| Full Fill Cavity Wall |
KORE Fill |
0.27 |
110mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.27 |
65mm Silver + 35mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
115mm Silver + 25mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
125mm Silver + 25mm Silver |
| Flat Ceiling |
KORE Pack |
0.16 |
225mm White |
| Product | Solution | U-Value | Type |
| Solid Ground Floor |
KORE Floor |
0.25 |
100mm White |
| Full Fill Cavity Wall |
KORE Fill |
0.27 |
110mm Silver |
| Partial Fill Cavity Wall |
KORE Key + KORE Linear Drylining |
0.27 |
65mm Silver + 35mm White |
| Warm Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
115mm Silver + 25mm Silver |
| Cold Pitched Roof |
KORE Lock + KORE Linear Drylining |
0.20 |
125mm Silver + 25mm Silver |
| Flat Ceiling |
KORE Pack |
0.16 |
225mm White |
Additional Specifications**
| A Grade | B Grade | C Grade |
| Glazing (W/m²K) |
0.8 - 1.3 |
1.8 - 2.2 |
2.6 |
| Airtightness (m³/hr/m²) |
2 |
5 |
Default Not Tested |
| Lighting (CFL) |
100% |
100% |
30% |
| Space Heating |
98% Oil |
95% Oil |
85% Oil |
| Water Heating |
4m² Solar Panels |
Heating System |
Heating System |
| Ventilation |
Heat Recovery 95% |
Natural |
Natural |
| Photovoltic |
5m² |
None |
None |
*The thickness of insulating material required to achieve a given U-Value can vary depending on the grade of material used and the exact application conditions. For different thickness options and advice please contact our technical department. Floor P/A taken as 0.5.
** The details above are designed as a guide. They are an indication of the U-Values required to meet Building Energy Ratings. Given that the elements of every dwelling will vary the above information is subject to change. It is vital that a fully qualified BER assessor undertakes the BER assessment to determine every individual dwelling requirement.
|