Technical Data Sheet
Download a copy of KORE Loft Technical Data Sheet. For further information please contact our technical team.
U-VALUE CALCULATION
Contact Airpacks technical department for further U-value calculations (Calculation Method I.S. EN ISO 6946) The Mineral Wool Insulation used in the calculation has a conductivity of 0.04W/mK.
U-VALUES: Attic at Ceiling Level
|
|
Thermal Conductivity
KORE Loft Panel
|
Insulation Over Joist
|
Insulation between Joist
|
| U-value 0.16W/m²K |
| 0.030 |
KORE Loft 70mm Silver SD |
150mm Mineral Wool |
| 0.030 |
KORE Loft 95mm Silver SD |
100mm Mineral Wool |
| U-value 0.13W/m²K |
| 0.030 |
KORE Loft 95mm Silver SD |
150mm Mineral Wool |
PHYSICAL PROPERTIES
| Properties |
Units |
Density |
| |
kg/m³ |
15-20 Standard |
SILVER EPS
|
| Thermal Conductivity |
W/mK |
0.030 |
| Compressive Strength |
kPa |
>95 |
| Bending Strength |
kPa |
>171.70 |
| Dimensional Strength |
DS(n) |
2 |
INSTALLATION
Place a suitable insulation material between the attic joists as normal.
Place the KORE Loft Sheets over the timber joists.
The Sheets easily slot in together. For extra stability screw fix the KORE Loft sheet to the joists.
Electrical cables running around the joists should be separated from the KORE Loft sheets by enclosing them with a suitable conduit.