Concrete Specification

Strength

25 Newton

Slump

Max 150mm

Aggregate – 150mm Concrete Core

10-13mm

Aggregate – 200mm Concrete Core

10-19mm



KORE Concrete Volume

Concrete
Thickness

Concrete Volume
m³ per m² Wall

150mm

0.150

200mm

0.200

300mm

0.300



Concrete Placement

Placement Method

Application

Advantages

Concrete Pump

Directly from discharge point into KORE Formwork

Different Pumps Reaches
Continuous Concrete Stream
Pump moves vertically & horizontally
High mobility and versatility

Crane & Skip

Used to place concrete from discharge point into KORE Formwork

Clean discharge
Various skip capacities available
Cranes have other uses on site

Hand

Directly from discharge point into KORE Formwork

Make up deficiencies at end of pour
Fill voids at cill area



KORE ICF U-value (W/m²K) Table

External
Finish

Concrete
Thickness (mm)

Concrete
Strength (N)

U-value
(W/m²K)

Render

150

25

0.20

Render

200

25

0.19

Render

150

30

0.20

Render

200

30

0.20

Brick

150

25

0.19

Brick

200

25

0.19

Brick

150

30

0.19

Brick

200

30

0.19

Note: KOREFill λ = 0.033W/mK